RightFax 8.7 Service Pack 3 for Server and Fax Board Drivers

This readme file provides late-breaking or other information that supplements the RightFax documentation. Service packs are the means by which RightFax product updates are distributed from the Captaris Web site. A service pack may contain updates for system reliability, program compatibility, performance improvements, and more. All service packs are cumulative. Each contains new fixes plus all the fixes from previous hot fix and service pack releases.  

This document describes the current update to this version of the RightFax server and fax board driver software. It provides installation instructions and a brief description of problems fixed with this release. Because Service Pack 3 is cumulative with Service Pack 2, a description of the changes in Service Pack 2 is included at the end of this document.

By the time you receive this software, updates to other RightFax software may be available. To obtain updates, go to http://www.captaris.com/customer_support.

Contents

  1. Determining Your Fax Server Type

  2. Installing Service Pack 3 for the RightFax Server

  3. Installing Service Pack 3 for the Fax Board Drivers

  4. Installing Service Pack 3 on Remote BoardServers

  5. Installing the Service Pack 3 Administrative Utilities

  6. Updating the RightFax Client Install Directory

  7. Software Fixes in Service Pack 3

  8. Documentation Additions and Corrections

  9. RightFax 8.7 Service Pack 2 for Server and Fax Board Drivers

Determining Your Fax Server Type

This service pack should be installed on computers that are running version 8.7 of all types of RightFax server. Follow these steps to confirm that a computer has this version of the RightFax server installed.

  1. From the computer desktop, select Start > Settings > Control Panel. If this computer is a RightFax server, the Control Panel includes an application called RightFax Server. If this application is not present, do not run the update program RightFax Server Update 8.70 SP3 Server Patch.exe on this computer.

  2. Double-click RightFax Server. The Server Configuration dialog box opens. The server version number and any installed service packs are displayed in the title bar of this dialog box. If the version number is anything other than 8.7 (with or without earlier installed service packs), do not run the update program RightFax Server Update 8.70 SP3 Server Patch.exe on this computer.

Installing Service Pack 3 for the RightFax Server

This service pack should be installed on all version 8.7 RightFax servers on your network. If you are running any RightFax Web applications on IIS servers or the Exchange 2000 connector on Exchange servers that are separate from the RightFax server, this service pack must be installed on those computers as well.

To update your software, Microsoft Windows Installer patches your existing RightFax installation by replacing existing files with updated files and installing new files.

Important: Before running this installation, if you have one or more Brooktrout TR1034 fax boards installed, you must confirm that the file bos_btcall.cfg in the \RightFax\RFBoard folder is not set to read-only. If it is, remove the read-only attribute from this file prior to installing the service pack. Running the service pack installation with this file set to read-only will fail to properly update the file and the fax boards will not operate.

  1. Log on to the RightFax 8.7 server as an administrator.

  2. Run the program RightFax Product Suite Service Pack 3.exe located on your update CD or extracted from the downloaded .zip file.

  3. At the introductory screen, click Update. A status bar indicates the progress of the installation.

  4. When the installation is complete, click Finish.

  5. After completing the service pack installation for the RightFax server, you must install the service pack for the fax board drivers (described in the next section) and the Web Client, if applicable.

  6. IMPORTANT: If you have any Brooktrout series 1034 fax boards already installed, you must re-configure these boards after upgrading to Service Pack 3. In this case, Captaris recommends removing and then re-adding the 1034 boards in the BoardServer Control Panel application.

Installing Service Pack 3 for the Fax Board Drivers

To update your software, Microsoft Windows Installer patches your existing RightFax installation by replacing existing files with updated files and installing new files. Follow these steps if your RightFax server has fax boards installed. If you use remote BoardServer computers, refer to the next section.

  1. When the installation of Service Pack 3 for the RightFax Server is complete, remain logged on to the RightFax 8.7 server as an administrator.

  2. Run the program RightFax Fax Board Driver Service Pack 3.exe that you extracted from the downloaded .zip file.

  3. At the introductory screen, click Update. A status bar indicates the progress of the installation.

  4. When the installation is complete, click Finish.

  5. The installation program includes Brooktrout TR1034 fax board firmware. If you have one of these fax boards installed, the TR1034’s flash ROM will need to be updated after applying this feature pack. Follow the steps in the next section to update the TR1034's flash ROM.

To Update the Flash ROM on Brooktrout TR1034 Fax Boards

  1. Stop the RightFax BoardServer service.

  2. If you did not install RightFax to the default location on the C: drive, navigate to the \RFBoard\Boston folder and edit the file flashupd.bat with a text editor. Confirm that the "SET LOADER=" parameter has the correct path to the file firm.exe. You must include both the path and file name in this parameter. For example:

    SET LOADER=\progra~1\rightfax\rfboard\firm.exe


    This command supports short file names only, so you may need to truncate folder names as in the example.
     

  3. Open a command prompt window and change to the \RFBoard\Boston folder.

  4. Run the following command:

    flashupd # [ENTER]


    Where # is the fax board's module number. If you do not know the board's module number, you can check by running this command:

    Modinfo [ENTER]


    The first 2 digits on the second line or output are the board's module number. For example, if the board's module number is 2, "02:" will be listed at the beginning of the second line.

    Important:
    Do not interrupt the flash update process. Doing so can permanently damage the fax board.

    A successful flash will display "Done, result value 0" on the last line. An unsuccessful flash will display "-1" on the last line.

  5. Repeat the flashupd command for each installed TR1034 fax board.

  6. Restart the RightFax BoardServer service.

  7. To confirm a proper flash update, run Enterprise Fax Manager and select the RightFax server name in the left pane. The ROM ID column should display "1.4.0 Build 38,38,38" for all fax channels not currently in use. When the RightFax BoardServer module running, the Board Status LED on each TR1034 board should be a slowly flashing green.

Installing Service Pack 3 on Remote BoardServers

Remote BoardServer computers must be updated immediately after the RightFax server is updated. To update remote BoardServer computers, you must update both the server software and the fax board drivers according to the instructions above.

Installing the Service Pack 3 Administrative Utilities

The RightFax Administrative Utilities are installed separately from other RightFax server and client components. Follow these steps to update the RightFax Administrative Utilities on all computers where they are already installed.

  1. Log on to the computer with the RightFax Administrative Utilities installed.

  2. Run the program RightFax Admin Utilities Service Pack 3.exe located on your update CD or extracted from the downloaded .zip file.

  3. At the introductory screen, click Update. A status bar indicates the progress of the installation.

  4. When the installation is complete, click Finish.

Updating the RightFax Client Install Folder

The RightFax Client Installs folder lets you store the RightFax client installation files on your network so that you can easily run all new RightFax client installations from that location. The installation files in this folder should be used for all new client installations. Existing clients should be upgraded by running the Service Pack 3 executable file directly on each client computer.

Follow these steps on the server where the version 8.7 RightFax Client Installs folder resides (described in the RightFax Installation Guide):

  1. This update can only be run on the base-level 8.7 Client Install folder. If you have already updated the RightFax Client Install folder to version 8.7 Service Pack 2, you must delete the RightFax Client Install folder and re-copy the base-level 8.7 Client Install Folder from the RightFax 8.7 CD before upgrading to Service Pack 3. Refer to the RightFax Installation Guide for information on copying the RightFax Client Install folder from the RightFax CD.

  2. Unzip RightFax Product Suite Service Pack 3.exe to a temporary location, e.g., the C:\temp folder.

  3. Open a command prompt window and navigate to the existing RightFax Client Installs folder.

  4. At the command prompt, type:

    "C:\temp\RightFax Product Suite Service Pack 3.exe " /V"/a RightF~1.msi
     

  5. Once the installer window is displayed, follow the on-screen prompts to update the client installs to service pack 3. If the installer fails to display or if you receive an error message, verify the path to the location where you installed the RightFax Product Suite Service Pack 3.exe file.

  6. After the RightFax client installs folder on your network has been upgraded, it should be used for new client installations only. If you want to upgrade existing RightFax client installations, you should run the Service Pack 3 executable file directly on each client computer.

Software Fixes in Service Pack 3

 

Captaris Tracking Number

Module

Problem

Solution

39839

Alerting

Fax channel monitoring reports error when last channel is selected. Monitors incorrect channels numbers.

Fax channel monitoring correctly monitors fax channels.

41470

BoardServer

When analog TR1034 fax boards are in use, the BoardServer does not correctly process DTMF digits for routing.

The BoardServer now processes DTMF digits for routing.

41767

BoardServer

The BoardServer module crashes if a dialing rule to disallow sending is listed after but matches the pattern of a previous rule.

The described behavior no longer occurs. Dialing rules are executed as expected.

42097

BoardServer

The file Callctrl.cfg includes incorrect syntax for the num_rings parameter.

This parameter has been corrected in Callctrl.cfg.

43357

BoardServer

Running the BoardServer module in debug mode through EFM pushes CPU usage to 100%.

Debug error corrected.

44160

BoardServer

ECM setting for Brooktrout boards stays enabled even if disabled in the BoardServer configuration application.

ECM setting now reads correct setting from the BoardServer configuration application as expected.

40068

Brooktrout TR1034

When restarting a RightFax server installed on a Compaq machine (e.g. DL380 G3), running Compaq's Surveyor utility with Windows 2003 Server, and Brooktrout TR1034 fax boards installed, the server hangs.

Hang on reboot problem resolved.

41948

Brooktrout TR1034

TR1034 boards configured for PRI-E1 have the pcm_law parameter configured incorrectly.

This parameter is now correctly configured as "alaw" instead of "mulaw."

41951

Brooktrout TR1034

Deactivating one or more channels on the TR1034 (PRI) is not reflected correctly in callctrl.cfg.

This value is now correctly written to Callctrl.cfg.

42242

Brooktrout TR1034

TR1034 analog channels report as "Offline Permanently" when in the same machine as digital TR1034 boards configured as PRI-ISDN.

TR1034 analog channels now function properly when in the same machine as digital TR1034 boards configured as PRI-ISDN.

42841

Brooktrout TR1034

TR1034 will not dial more than 24 digits.

Corrected. Unlimited dialing characters supported.

44021

Brooktrout TR1034

TR1034 BRI boards fail to receive faxes via the Siemens HiPath PBX.

TR1034 BRI boards now correctly receive faxes via the Siemens HiPath PBX.

44089

Brooktrout TR1034

Frequent channel reset failures on inbound faxes when running one or more TR1034+P4-4L boards with RightFax 8.7 FP1 with IBM Series 235.

Channel reset problem resolved.

44220

Brooktrout TR1034

DTMF routing for a fax channel with the option "Initial Speech" set requires users to wait for the entire voice greeting to end before the system will accept entered digits.

Routing digits can now be entered at any time during the voice prompt.

44271

Brooktrout TR1034

Eccdlld.dll file not found error when running voice.exe for the TR1034 board.

Voice.exe now finds eccdlld.dll as expected.

37114

ChgUser.exe

When running ChgUser.exe and the NONTSECURITY keyword is used in the command line, the "Stamp Pages of Received Faxes with Audit Stamp" option is enabled in the user record.  

The NONTSECURITY keyword in ChgUser.exe no longer automatically enables the "Stamp Pages of Received Faxes with Audit Stamp" option.

41293

E-mail Gateways

After a Satellite Server is bumped, the cc:Mail, MS Mail, Groupwise, and SMTP E-mail Gateways are unavailable for install.

Bumping a Satellite Server now makes these e-mail Gateways available.

42833

Embedded Codes

After upgrading from RightFax 7.2 to RightFax 8.7, some embedded codes (such as NEWDEST) inappropriately generate a fax cover sheet.

Embedded codes no longer inappropriately generate fax cover sheets.

42217

Enterprise Fax Manager

Selecting the option  "Disallow Fax Annotation" also disables the ability to print, forward, route, and more.

Selecting the option  "Disallow Fax Annotation" no longer affects other user permissions.

35668

Exchange Gateway

The option to "Break up Large Faxes" sends faxes above the specified page limit.

The option to "Break up Large Faxes" now correctly sends faxes at the specified page limit.

42103

Exchange Connector

Faxes routed to e-mail via the Exchange connector use full path to the attachment for the file name, which made the file unreadable by certain devices.

Faxes routed to e-mail via the Exchange connector no longer include the full path in the file name.

44119

Exchange Connector

Exchange 5.5 displays warnings for every processed fax if you have Message Tracking enabled on the connector.

Problem fixed. Warning messages no longer appear.

44963

Exchange Connector

Microsoft Exchange System Manager crashes when adding a user that is not in the Users container on the Delivery Restrictions tab.

This action no longer crashes Microsoft Exchange System Manager.

41685

Fax Control

Print-to-Fax on a file with a long file name (150 characters or higher) fails.

Print-to-Fax on files with long file names (150 characters or higher) work as expected.

41973

Fax Control

JPEG files converted to fax format appear small and compressed.

JPEG files now convert to fax format as expected.

45057

Fax Control

When using the Quick Fax/Broadcast feature, users can change phonebook entries even when not assigned this permission.

Quick Fax/Broadcast feature now correctly blocks users from changing phonebook entries if they are not assigned this permission.

30461

Fax Reporter

In Fax Reporter, the Folder column in the Faxes table is not populated correctly.

Folder column in the Faxes table now reports folder names as expected.

31869

Fax Reporter

FaxReporter misreports scheduled send time in the FaxSendDateTime column if a fax was delayed.

Delayed faxes now correctly report the scheduled send time in the FaxSendDateTime column.

42209/
44020

Fax Reporter

Fax Reporter data does not refresh if the network protocol is set to TCP/IP and then changed to either Named Pipes or Automatic Selection.

Fax Reporter data now correctly refreshes if network protocol setting is changed.

41543

Fax Server

"Fax not viewed or printed" notifications are always sent to the Group Administrator when users route faxes to an E-mail Gateway, even if option for no notifications is selected.

The option for to disable notifications to the Group Administrator now works as expected.

44243

Fax Server

Applying Tracks patch 40069 causes files to be routed in 8.3.3 file format instead of an 8.3 format.

Applying Tracks patch 40069 now correctly causes files to be routed in 8.3 format.

42494

Fax Status

Fax Status application crashes when viewing the status of a fax channel transmitting at V.34.

Fax Status application no longer fails when viewing v.34 transmissions.

41673

FaxUtil

Odd-sized tiff images, when sent as file attachments, fail to convert.

Attached tiff images convert as expected.

41682

FaxUtil

FaxUtil will not run if no RightFax server name was specified during client installation.

Leaving the RightFax server name blank during installation no longer causes FaxUtil to fail.

41742

FaxUtil

After closing the Phonebook window, faxes appear to lose their corresponding filter information (sent/received, to/from/file, etc.). Deleting one of these faxes causes FaxUtil to appear to perpetually delete faxes.

The described behavior no longer occurs and deleting faxes works as expected.

41822

FaxUtil

FaxUtil folders default to the order they were created, even if alphabetical order is specified.

FaxUtil folders now correctly display in alphabetical order.

41890

FaxUtil

FaxUtil lists the same fax repeatedly after opening the Fax Viewer, forwarding to new number, and then using the phonebook to select a recipient.

Corrected so that no duplicate fax entry is displayed.

43987

FaxUtil

FaxUtil lists the same fax repeatedly after opening the Fax Viewer, forwarding to new number, and then using the phonebook to select a recipient.

Corrected so that no duplicate fax entry is displayed.

44707

FaxUtil

Faxes that are in the "Needs Approval" status will not go back to that status after printing. Status stays as "Printing" indefinitely.

After printing a fax in the "Needs Approval" state, fax returns from status "Printing" to status "Needs Approval."

44833

FaxUtil

Attached text files that contain tab characters do not word wrap correctly on conversion to fax format.

You can now customize the maximum number of characters per line. Navigate to the registry key HKEY_LOCAL_MACHINE
\Software\Rightfax\Workserver\WorkSrv#, add a new DWORD registry called WordWrapTextLength, and set the data for this new value to the maximum number of characters per line (e.g. 76). After adding this registry value, Open the WorkServer configuration application and select the option Use PCL Converter for Text Files. Then, restart the services.

45841

FaxUtil

When attempting to send a fax to an Outlook 2003 MAPI phonebook contact, FaxUtil generates a Dr. Watson error. Occurs only when an Outlook 2003 client has "Use cached exchange mode" enabled.

Error no longer occurs.

43661

FileNet Connector

The connector fails to process jobs from multiple source servers.

The connector now supports job processing from multiple servers as expected.

41854

Human-Answered Fax

Selecting the option "Always start each call in voice mode" causes the fax board to automatically hang up after 12 seconds on outbound calls.

Selecting the option "Always start each call in voice mode" no longer causes the fax board to automatically hang up.

42503

Human-Answered Fax

The Human-Answered Fax feature, using TR1034 analog boards with the "Always start" option enabled, reports status "OK" when dialing times out without an answer.

Faxes now correctly report status "No answer at fax number."

42534

Human-Answered Fax

The Human-Answered Fax feature, using TR1034 analog boards with the "Always start" option enabled, reports status "OK" when a busy signal is encountered.

Faxes now correctly report status "Busy."

32530

ImpUser.exe

The last entry in a .csv file fails to import unless a carriage return follows.

Fixed so that carriage return is no longer required.

33203

ImpUser.exe

All users exported from RightFax and re-imported using ImpUser .exe have "Delete After Routing" option enabled.

ImpUser.exe now correctly retains  "Delete After Routing" setting.

41750

Mimesend

Mimesend fails to send to all recipients if any single recipient in a particular group has a bad e-mail address.

Mimesend now ignores only the bad e-mail addresses and sends to all others as expected.

41611

Notes Gateway

Under certain circumstances, user synchronization between Notes and RightFax was incorrectly synching changes to Notes users with the RightFax server when synchronization was specifically set to only flow from RightFax to Notes.

Corrected directional synchronization error.

37666

ODBCSync.exe

When synching a new user into a group whose name contains a space, the new user is not created in RightFax.

RightFax now correctly reformats the group name, replacing spaces with underscore characters, and adds the user to the new group.

39682

ODBCSync.exe

When synching a new user whose name contains a space, the new user created with an underscore replacing the space as expected, but re-running ODBCSync.exe will generate arror and fail to update these users.

Importing user names with spaces no longer generates error and updates as expected.

40310

ODBCSync.exe

RightFax IDs that have been created with ODBCSync.exe and had a source ID more than 21 characters long fail to update when re-running ODBCSync.exe.

Importing user names with more than 21 characters no longer generates error and updates as expected.

41814

Outlook Advanced Form

The "Delay Send" option on the Outlook Advanced form shows the Date field twice instead of Date and Time.

The "Delay Send" option on the Outlook Advanced form now correctly shows Date and Time fields.

43610

Outlook Advanced Form

Some faxes appear blank when viewed with the Outlook Advanced Form with Outlook 2003.

All faxes now display as expected.

43913

Outlook Advanced Form

Outlook 2003 terminates unexpectedly when opened minimized and custom user variables exist with Outlook Extensions installed.

Outlook 2003 no longer terminates when minimized and then closed.

45705

Outlook Advanced Form

Outlook hangs when receiving a fax in Outlook with McAfee 8.0i enterprise installed.

Outlook no longer hangs on receiving a fax.

31969

PDF

PostScript documents that contain the PostScript command "setpagedevice" fail conversion to fax format for transmission.

The PostScript command "setpagedevice" is now processed correctly and does not cause fax conversion failure.

41573

PDF

Adobe 6 PDF images acquired using TWAIN scanners shrink to 1/3 original size.

Adobe 6 images now attach at full size.

41676

PDF

Compressed PDF file fails conversion.

Compressed PDF files convert as expected. Requires SSA NativeDocControl PDF,2 for WorkServer.

42263

PDF

PDFs with embedded Asian fonts convert incorrectly to fax format.

Asian fonts now convert to fax format as expected.

42693

PDF

The -d switch for Pssplit.exe does not cause debug information to write to the screen or event viewer.

The -d switch for Pssplit.exe now correctly outputs debug information.

43227

PDF

Converting a document that contains a barcode font to PDF using NativeDocControl fails to properly convert the barcode.

Corrected. The font is properly converted when corresponding .TTF file is located in the Worksrv\Fonts folder.

43377

PDF

PDF images generated on the HP4100 have stripes running through the image.

Problem corrected. PDF images convert as expected.

44108

PDF

PDFs created from documents with graphic images in the header or footer convert with poor image quality.

Graphic conversion corrected to retain image quality.

34653

PhnPrint.exe

PhnPrint.exe commands that specify multiple users but only supply some of the users' passwords outputs data as though no passwords had been supplied.

PhnPrint.exe now recognizes a partial list of passwords and outputs data accordingly.

42555

PhnPrint.exe

Level 2 output for PhnPrint.exe does not output all expected data fields.

Level 2 output for PhnPrint.exe corrected so that it now outputs all expected data fields.

35199

Production

The Mailsend.exe  -o switch converts all recipient e-mail address to ASCII, causing mail transmission failure.

Mailsend.exe -o switch preserves recipient e-mail addresses correctly and mail transmits as expected.

37199

Production

Bumping a Business Server with the Integration Module enables no production fax channels.

The production fax channels are now correctly enabled when a Business Server with Integration is bumped.

41396

Production

MapText.exe image preview does not work.

MapText.exe image preview works as expected.

42954

Production

When PORTLSTN.exe is enabled in the Integration Module control panel application, a Dr. Watson error is reported when the Integration Module service is stopped.

Corrected issue. Dr. Watson error no longer occurs.

43168

Production

Running NOTIFY.exe to add a new integration channel causes a Dr. Watson error when the Integration Module service is stopped.

Corrected issue. Dr. Watson error no longer occurs.

34724

Rescue.exe

Running Rescue.exe causes all faxes that are currently waiting for transmission because a delay time was specified to fail to send.

Rescue.exe now correctly preserves delayed faxes. Delayed faxes transmit at the specified time as expected.

41840

SAP

The ProgID parameter in the saprfc.ini file is always reset to servername.sapgate when closing configuration.

The ProgID parameter now retains its correct setting when closing configuration.

41894

SAP

All faxes sent via SAPOffice are sent as high priority.

Faxes sent via SAPOffice now send with normal priority unless otherwise specified.

44203

SAP

SAPGate strips out data beginning with "<who".

SAP no longer strips invalid SAP embedded code text.

44227

SAP

If you add DefaultUserID as a Reg_SZ value to HKLM\Software\RightFax\SAP\SAP#\ and send a fax through that SAP Gateway, it will not send from the user specified in that key, but will send using the Default user ID instead.

Registry setting now correctly read by SAP connector.

12459

SecureDocs

Non-US regional settings cause an inability to log in to SecureDocs .

Corrected date formatting to allow login with non-US regional settings.

43116

SecureDocs

Under certain circumstances, user administration through SecureDocs fails.

Corrected error so that user administration works as expected.

41270

SMTP Gateway

Submitting an e-mail to the SMTP Gateway that has embedded HTML in the body with embedded images causes the Gateway to stop unexpectedly.

The SMTP Gateway now correctly processes HTML-referenced images.

42990

SMTP Gateway

A fax with an attachment that is sent through the SMTP Gateway and fails conversion is incorrectly deleted from FaxUtil.

The behavior in this circumstance is now configurable in the registry. To retain these faxes in FaxUtil with a "failed" status, navigate to the registry key HKEY_LOCAL_MACHINE\Software\Rightfax\Faxserver

and set AutoDeleteFailedGatewayFaxes to 0. To retain the functionality as described, set AutoDeleteFailedGatewayFaxes to 1.

43282

SMTP Gateway

Fax conversion error notifications are returned to the sender via e-mail, even if all notification options are disabled.

This behavior is now configurable in the registry. To disable these notifications, navigate to the registry key HKEY_LOCAL_MACHINE\Software\Rightfax\Faxserver, add a new DWORD registry called NoGatewayNotify, and set the data for this new value to 1.

46915

Standalone Fax Connector

Standalone Fax Connector does not work with TR1034 analog boards.

Connector now dials out as expected.

40288

Web Client

Attaching notes in Web Client loses all characters after 80 if manual carriage returns are not entered.

You can now customize the maximum number of characters per line. Navigate to the registry key HKEY_LOCAL_MACHINE
\Software\Rightfax\Workserver\WorkSrv#, add a new DWORD registry called WordWrapTextLength, and set the data for this new value to the maximum number of characters per line (e.g. 76). After adding this registry value, Open the WorkServer configuration application and select the option Use PCL Converter for Text Files. Then, restart the services.

35216

WorkServer

WorkServer archiving of outbound documents fails when sending to an e-mail address.

Faxes sent to e-mail addresses are now archived as expected.

41911

WorkServer

Autoprinting inbound faxes to an HP LaserJet 4si prints only a single black line.

HP LaserJet 4si printers now autoprint correctly.

43699

WorkServer

Conversion of some JPEG images results in poor image quality, especially when converting colors to grayscale.

You can now customize the threshold setting when converting JPEG images to grayscale. Navigate to the registry key HKEY_LOCAL_MACHINE\Software\Rightfax\Workserver, add a new DWORD registry called RFThresh, and set the data for this new value to an appropriate setting from 3-255. The default value used is 128. Increase this value to darken color images. To change the registry value, stop all WorkServers, change the registry value on the server, then restart the WorkServers.

44398

WorkServer

WorkServer fails to create TIFF-G4 for certain received faxes when routing to network directory.

Problem corrected. TIFF-G4 created as expected.

Documentation Additions and Corrections

The additions and corrections listed here apply only to the 8.7 version of the RightFax documentation.

RightFax 8.7 Administrators Guide

Chapter

Various

Section

Various

Page

Various

Error

Documentation does not state that the <SIGNATURE> embedded code is unsupported in outbound PDF documents.

Resolution

Please note that the <SIGNATURE> embedded code is not supported in outbound PDF documents.

 

 

 

 

Chapter

6, "Enabling Active Directory User Synchronization"

Section

"Configuring the RightFax WorkServers to Perform User Synchronization"

Page

103

Error

Information about the WorkServer's service account is omitted, which may cause automatic Active Directory user updates to fail.

Resolution

The WorkServer service account must reside in the domain with which it is synchronizing so that updates to Active Directory user IDs are reflected on corresponding RightFax IDs after the initial synchronization has occurred.

 

 

 

 

Chapter

9, "Creating Groups of Users"

Section

"Editing Group Properties"

Page

155

Error

The definition for the option Days to keep deleted fax records on the Group Edit dialog box Basic Information tab is misleading.

Resolution

The documentation implies that fax records will be retained in the database for the number of days specified in the Days to keep deleted fax records option after the fax image is deleted. In fact, the fax records will be retained in the database for this number of days after the fax is received. You should set the Days to keep deleted fax records value based on the received date rather than the delete date. If you have set users' faxes to be automatically deleted after 30 days, and want the fax records purged 30 days later, then set the Days to keep deleted fax records to 60 days.

 

 

 

 

RightFax 8.7 Installation Guide

Chapter

4, "Installing the RightFax Client Applications"

Section

"MAPI Print Driver," "VIM Print Driver"

Page

43

Error

Documentation fails to mention that VIM and MAPI printing are not supported under Windows 2003 Terminal Server.

Resolution

Please note that VIM and MAPI printing are not supported under Windows 2003 Terminal Server.

 

 

 

 

 

RightFax 8.7 Service Pack 2 for Server and Fax Board Drivers

This document provides late-breaking or other information that supplements the RightFax documentation. Service packs are the means by which RightFax product updates are distributed from the Captaris Web site. A service pack may contain updates for system reliability, program compatibility, performance improvements, and more. All service packs are cumulative. Each contains new fixes plus all the fixes from previous hot fix and service pack releases.

This document describes the current update to this version of the RightFax server and fax board driver software. It provides installation instructions and a brief description of problems fixed with this release.

By the time you receive this software, updates to other RightFax software may be available. To obtain updates, go to http://www.captaris.com/customer_support.

Contents

  1. Software Fixes in Service Pack 2

  2. Documentation Additions and Corrections

  3. Additional Brooktrout Fax Board Support

  4. Configuring Automatic Timeout for Failed Server-Side Application Conversions

Software Fixes in Service Pack 2

 

Captaris Tracking Number

Module

Problem

Solution

39669

Alerting

An alert condition fails to send email.

Now an alert condition sends email successfully.

39522

BoardServer

Making changes to the BoardServer configuration can add multiple instances of Boston/BFax to the RFBOARD DependOnService registry value.

Making changes to the BoardServer configuration no longer adds multiple instances of Boston/BFax to the RFBOARD DependOnService registry value.

39968

BoardServer

All failed phone calls become failed faxes in PRI-E1 on TR1034.

Failed phone calls no longer report incorrectly as failed faxes in PRI-E1 on TR1034 boards.

39977

BoardServer

Selecting the "Enable Overlap Receive" option in DCW for 1034-E1 board does not stick.

The "Enable Overlap Receive" option in the Digital Configuration Wizard for 1034-E1 fax boards now properly retains its value.

39996

BoardServer

Atempting to open the BoardServer control panel applet results in "GetBump" errors.

Opening the BoardServer application no longer gives "GetBump" errors.

39757

FaxUtil

Install of RightFax 8.7 client after installing Paperport Pro version 9 Office on XP Professional machine fails.

First install RightFax 8.7 client and then install Paperport Pro 9. If Paperport Pro 9 is already installed, manually uninstall it, install RightFax 8.7 client, and then reinstall Paperport Pro 9 and the scanner driver.

39465

Database/Server

RightFax Server and Database modules fail to start in debug mode at the command prompt.

Now RightFax Server and Database modules can run in debug mode at the command prompt.

39523

EDC Configuration

Cannot download Xerox 8.7 templates to WorkCenter 55.

Now can download the Xerox 8.7 templates.

42346

EDC Configuration

Using Xerox 8.7, sending a fax from WalkupFax, SecureDocs, or Certified Delivery templates, ensuring you populate the ReplyTo field, the sender is not notified of the job status.

Now when the Reply To field is used, the sender is notified of the job status.

36940

EDC

After sending a fax, get a Job Failure notice in RFSendStatus. FaxUtil shows it sending with no sender and no recipient. It does eventually send, although no RightFax server receives it.

Now it processes the fax and the monitor does not indicate a job failure.

40037

Exchange Connector

Exchange 2003 stops the RightFax Connector from processing if too many messages are sent.

A registry value is available to enable the initiation of a new MAPI session every time the Exchange server processes 100 messages.

  1. Open the Registry Editor and navigate to HKLM> Software> RightFax> Gateway.

  2. Create a new REG_DWORD value and name it AvoidServerLimits.

  3. Set the value to 1 and exit the Registry Editor.

Note:  May need to manually create the Gateway subkey.

38796

Exchange Gateway

When manually address a fax from Outlook that contains a plus sign (+) as the first character in the fax number, the exchange gateway strips the entire number.

Now the exchange gateway does not attempt to strip the plus sign, and the fax can be sent manually from Outlook.

39683

Fax Server

Error encountered, fax will be abandoned notifications are sending During transmission messages.

Now Error encountered, fax will be abandoned notifications use the correct text.

39695

Fax Server

Automatically forwarding a fax generates a false error message in the event viewer.

Now automatically forwarding a fax does not generate a false error message in the event viewer.

39947

Fax Server

Transmission error faxes received by users that route to the Exchange gateway are scheduled to be sent.

Now received faxes are not scheduled to be sent.

41330

Fax Server

Having the Admin ONCE Only option disabled and Admin Notify Time set to zero results in many group administrator notifications of faxes not viewed or printed.

Having the Admin ONCE Only option disabled and Admin Notify Time set to zero disables all group administrator notifications of faxes not viewed or printed.

40407

Fax Viewer

When using the CTRL key and the Up or Down arrow in the Rightfax Viewer, the Viewer does not scroll from fax to fax.

Now can view the next fax and previous fax when using the CTRL key and the Up or Down arrow in the RightFax Viewer.

40246

Installation

An incorrect fax.exe is installed in the \RFBoard\Boston\ folder.

The correct version of fax.exe is now installed in the \RFBoard\Boston folder for fax board testing.

39983

Notes Client

 

Using French EFM Sync and creating a new default user with PRESONNE_ PAR_DEFAUT ID, cannot synchronize user into RightFax server.

Now the localized EFM Sync does not translate system variables; DEFAULT remains default and synchronization works.

 

39999

Notes Client

Notes users can not select the Forward button in the Notes mail template to forward messages in the Inbox  to other Notes users. The error  "Cannot locate Default Form" is displayed.

For version 8.7 there is a workaround for this problem. Refer to TechNote #11528 on the Captaris Web site for instructions.

39985

Notes Gateway

Using French EFM Sync, creating a new default user with PRESONNE_ PAR_DEFAUT ID, and sending a fax from a user that is not an EFM Sync user, fax fails to send.

Now the translation is handled appropriately and faxes can be sent.

39788

Production Server

When sending a Fax Control Language document and checking Do Not Delete Input Files, a fax is not created.

Now a fax is created and the input file is not deleted.Note:  This creates a subfolder in the monitored folder (usually the Inbox) called Archive into which processed faxes are placed.

39790

Production Server

Registry entries are removed when saving settings in the Integration Module Configuration GUI.

The new control panel contains a "Download image as TIFF" checkbox that can be set.

39950

Production Server

The parser crashes if it receives an email document with more than 135 lines of body text.

The parser no longer crashes with more than 135 lines of body text.

37356

SMTP Integration

The SMTP Gateway crashes when attempting to route a fax if communication with the SMTP server is lost.

Now the SMTP Gateway continues attempting to process faxes.

37780

SSA

When using Office XP for SSA, sending Word cover sheets and/or documents in high volume can cause the WorkServer to crash.

Now the WorkServer does not crash.

40046

SSA

When using SSA to convert Excel documents, instances of Excel.exe continually spawn and remain open.

Now instances of Excel.exe spawn and close after conversion.

34585

WorkServer

PCL files created with Macro4 convert with what appears to be all 5 pages overlayed on one page.

PCL files created with Macro4 now convert successfully when sent as attachments.

38828

WorkServer

Active directory synchronization fails if the permission to read an object or Organization Unit is removed from the Everyone group.

Now Active Directory synchronization does not fail in this situation.

39517

WorkServer

Automatically printing only the history on sent faxes fails using Windows GDI printers.

Now the history prints successfully.

39873

WorkServer

In certain circumstances, workservers loop on conversion when trying to use SSA, but the native document application is either not installed or could not be loaded, creating very large temporary files.

Large temporary files are no longer created.

40069

WorkServer

Routing a fax to a network directory does not work when using PCX or DCX as the file format.

Now correctly creates PCX or DCX files in the target directory.

40405

WorkServer

Images acquired through TWAIN scanners, e.g., BMP files, experience excessive shrinkage.

Now scanned documents experience very little or no shrinkage of their size.

41300

WorkServer

PCX file attachments fail conversion.

Now the fax converts successfully.

Documentation Additions and Corrections

The additions and corrections listed here apply only to the 8.7 version of the RightFax documentation.

RightFax 8.7 Gateway for Microsoft Exchange Guide

Chapter

3, "Installing the RightFax Connector for Microsoft Exchange 2000 and 2003"

Section

"Changing the mail directory paths"

Page

30

Error

A step is missing from this procedure.

Resolution

Add this step after step 4: "For the second node only, remove the FAX* and RFAX* namespace."

 

 

 

 

Chapter

5, "Configuring Outlook Users to Send and Receive Faxes"

Section

"Configuring Outlook Users to Send and Receive Faxes"

Page

39

Error

Right-click options are incorrect.

Resolution

The options listed in the guide are  View, Delete, and Release a fax held for preview. Options should read "Refresh, View, and Delete."

 

 

 

 

RightFax 8.7 Administrators Guide

Chapter

3, "Configuring the RightFax Server Module"

Section

"Installing the RightFax Server Software"

Page

31

Error

The location of the Administrative Utilities installation is incorrect.

Resolution

The correct location is Support\Admin Utilities\Setup.exe.

 

 

 

 

RightFax 8.7 Installation Guide

Appendix

A, "Installing RightFax in a Windows 2000 or Windows 2003 Cluster"

Section

"Configuring the shared drive"

Page

56

Error

The location for the Setup.ini file is incorrect.

Resolution

The instructions should read "Using a text editor, edit the file Setup.ini located in the folder where you placed the RightFax client installation files (described in the RightFax Installation Guide). By default, this is installed in C:\RightFax Clients. Change the RFSERVERNAME value to the name of the cluster.

 

 

 

 

RightFax 8.7 Integration Module Guide

Appendix

B, FCL Commands"

Section

"{{ATTACH}}"

Page

250

Error

The guide does not mention that the {{type email}} command can not be used in combination with the {{attach}} command.

Resolution

The {{type email}} command can not be used in combination with the {{attach}} command.

 

 

 

 

RightFax 8.7 Gateway for Lotus Notes Guide

Chapter

N/A

Section

N/A

Page

N/A

Error

Notes users can not select the Forward button in the Notes mail template to forward messages in the Inbox  to other Notes users. The error  "Cannot locate Default Form" is displayed.

Resolution

For version 8.7 there is a workaround for this problem. Refer to TechNote #11528 on the Captaris Web site for instructions.

 

 

 

 

Additional Brooktrout Fax Board Support

Service Pack 2 for RightFax version 8.7 includes support for the following Brooktrout fax boards:

After Service Pack 2 has been installed, these fax boards may be added and configured in the RightFax BoardServer application in Windows Control Panel. For information on running the RightFax BoardServer application, refer to the RightFax Administrator's Guide.

Preparing the Fax Boards

Before installing any of the new fax boards into the server chassis, you must assign each board a unique "module number." The module number is set using a rotary switch located on the fax board. Refer to your Brooktrout documentation for the location of the rotary switch on your particular fax board model.

Warning: Do not use a pencil or any other object that conducts electricity to move the rotary switch on Brooktrout fax boards. Using graphite and other electrically conductive materials may cause severe damage to the board.

The module number must be unique for each fax board you are installing in a single computer (i.e., you cannot have two fax boards in the same computer with the same module number setting). Module numbers do not need to be sequential. Also, do not set the module number on any Brooktrout fax board to 0 or 1 (these values are reserved by Brooktrout for diagnostic purposes.) Make a note of the module numbers you assign to each installed fax board. You will need to enter this information when configuring the RightFax software to communicate with the boards.

After the module numbers have been set on each fax board, you should install them into the server chassis.

Configuring the Fax Boards for Use With RightFax

After the fax boards have been installed in the server, you must configure the boards for use with RightFax.

IMPORTANT: If you have any Brooktrout series 1034 fax boards already installed, you must reconfigure these boards after upgrading to Feature Pack 1. In this case, Captaris recommends removing and then re-adding the 1034 boards in the BoardServer Control Panel application.

Configuring Automatic Timeout for Failed Server-Side Application Conversions

If, for any reason, server-side application conversion fails, you can configure RightFax to automatically timeout, stop the conversion, and set the fax status to conversion failed.

  1. On the RightFax server, stop all WorkServer services.

  2. Edit the Windows Registry on the RightFax server.

  3. For each WorkServer number (\Worksrv#) add a REG_DWORD value called KillServiceTimeout to HKEY_LOCAL_MACHINE\Software\RightFax\Workserver\Worksrv# and set the data value to the length of time you want server-side application conversion to attempt conversion before timing out, in milliseconds (i.e., set the data value to 600000 for 10 minutes).

  4. Restart the services.

To have the WorkServers recover after being stopped by this new feature, open the Windows Control Panel and select Administrative Tools > Services > RightFax WorkServer and go to the Recovery tab to select the service's response to the shutdown.